This chapter describes ESCON Network Interface (ESC) messages. For information on message content and how to use the message, refer to the Introduction.
ESC.001 |
Level: ALWAYS
Short Syntax: ESC.001 bd frm LANtype lan_type LANnum lan_num on nt network
Long Syntax: ESC.001 frame received for unknown LAN type lan_type, LAN number lan_num on network network
Description: A frame was received from the channel destined for an unknown LAN type or LAN number.
ESC.002 |
Level: ALWAYS
Short Syntax: ESC.002 bd not not_id on nt network
Long Syntax: ESC.002 unknown notification not_id received from device driver on network network
Description: A notification was received from the device driver that was unknown.
ESC.003 |
Level: UE-ERROR
Short Syntax: ESC.003 bd 8232 cmd cmd on nt network
Long Syntax: ESC.003 unknown 8232 command cmd received on network network
Description: An 8232 command was received that was unknown.
ESC.004 |
Level: ALWAYS
Short Syntax: ESC.004 bd cmd cmd on nt network
Long Syntax: ESC.004 unknown IORB command cmd received on network network
Description: An IORB was received that contained an unknown command.
ESC.005 |
Level: ALWAYS
Short Syntax: ESC.005 no subch on nt network
Long Syntax: ESC.005 no subchannels are defined on network network, cannot pass self-test
Description: There are no subchannels defined for an ESCON base net so the network cannot be activated (pass self-test).
Cause: The virtual net handler(s) for this base net handler has (have) not been defined correctly.
Action: Define subchannels for the virtual net handler(s) on this ESCON adapter.
ESC.006 |
Level: UI-ERROR
Short Syntax: ESC.006 STOP: no IORB on nt network
Long Syntax: ESC.006 network network was unable to send a STOP command to the device driver because an IORB was not available
Description: The network was unable to complete deactivation because there was no IORB available with which to send the STOP command to the device driver.
ESC.007 |
Level: P-TRACE
Short Syntax: ESC.007 frm sent to lt lantype ln lannumber on nt network
Long Syntax: ESC.007 A frame was sent to LAN type lantype, LAN number lannumber on network network
Description: A frame was received on the channel and sent to a virtual net handler.
ESC.008 |
Level: P-TRACE
Short Syntax: ESC.008 data frm rcvd from nt network
Long Syntax: ESC.008 A data frame was received from network network
Description: A data frame was received from a virtual net handler to send to the channel.
ESC.009 |
Level: P-TRACE
Short Syntax: ESC.009 cmd cmd_code in frm rcvd from nt network
Long Syntax: ESC.009 command cmd_code in frame received from network network
Description: A command frame was received from a virtual net handler to send to the channel.
ESC.010 |
Level: P-TRACE
Short Syntax: ESC.010 notif notif_code rcvd on nt network
Long Syntax: ESC.010 notification notif_code received from device driver on network network
Description: A notification was received from the device driver.
ESC.011 |
Level: P-TRACE
Short Syntax: ESC.011 8232 cmd cmd_code rcvd on nt network
Long Syntax: ESC.011 8232 command cmd_code received on network network
Description: An 8232 command was received by the base net handler.
ESC.012 |
Level: C-TRACE
Short Syntax: ESC.012 nt virtual_net_number reg on nt network
Long Syntax: ESC.012 Network number virtual_net_number registering on base network network
Description: A virtual net handler is registering with an ESCON base net handler.
ESC.013 |
Level: P-TRACE
Short Syntax: ESC.013 Cmd cmd_code fail stat cmd_status on nt network
Long Syntax: ESC.013 Command cmd_code to device driver failed with status cmd_status on network network
Description: A command that the base net handler sent to the device driver has failed.
ESC.014 |
Level: P-TRACE
Short Syntax: ESC.014 Cmd cmd_code sent to DD on nt network (sub locaddr locaddr devaddr devaddr logpath logpath )
Long Syntax: ESC.014 Commands cmd_code was sent to the device driver on network network (subchannel local address locaddr, device address devaddr, logical path logpath)
Description: A command was sent to the device driver.
ESC.015 |
Level: P-TRACE
Short Syntax: ESC.015 Snd 8232 resp cmd_code (rc retcode) on nt network (sub locaddr locaddr devaddr devaddr logpath logpath )
Long Syntax: ESC.015 Sending 8232 response for command cmd_code with return code retcode on network network (subchannel local address locaddr, device address devaddr, logical path logpath)
Description: An 8232 response was sent to the host.
ESC.016 |
Level: P-TRACE
Short Syntax: ESC.016 Snd not notification_id to net virt_net_number on nt network
Long Syntax: ESC.016 Sending notification notification_id to net virt_net_number on network network
Description: A notification was sent to a virtual net handler from the base net handler.
ESC.017 |
Level: U-TRACE
Short Syntax: ESC.017 circdn for nt net_num on nt network
Long Syntax: ESC.017 circdown for net net_num called on network network
Description: The circuit down routine for a network has been called.
ESC.018 |
Level: U-TRACE
Short Syntax: ESC.018 circup for nt net_num on nt network
Long Syntax: ESC.018 circup for net net_num called on network network
Description: The circuit up routine for a network has been called.
ESC.019 |
Level: U-TRACE
Short Syntax: ESC.019 net up for nt net_num on nt network
Long Syntax: ESC.019 net up for net net_num called on network network
Description: The net up routine for a virtual network has been called.
ESC.020 |
Level: U-TRACE
Short Syntax: ESC.020 net dn for nt net_num on nt network
Long Syntax: ESC.020 net down for net net_num called on network network
Description: The net down routine for a virtual network has been called.
ESC.021 |
Level: UE_ERROR
Short Syntax: ESC.021 file( line): input fsminput curr stte curr_state new stte new_state actn action subchan network/ )
Long Syntax: ESC.021 file( line): input fsminput current state curr_state new state new_state action action subchannel network/ )
Description: Show the inputs to the FSM that is given in the message.
ESC.022 |
Level: UI-ERROR
Short Syntax: ESC.022 ESCON DD(slot slot adapter): Transmit List full threshold= count.
Long Syntax: ESC.022 ESCON DD(slot slot adapter): Transmit List full threshold= count.
Description: The device driver requires a transmit list entry in order to send data to the adapter. If the adapter cannot obtain an entry during initialization, the adapter will be restarted. If the adapter cannot obtain an entry at any other time, the internal software will attempt to recover. This error will only cause real problems for LSA.
Action: If the problem persists, contact Software Support.
ESC.028 |
Level: UI-ERROR
Short Syntax: ESC.028 ESCON DD asked to free private buffer 0x iob twice for adapter in slot slot.
Long Syntax: ESC.028 ESCON DD asked to free private buffer 0x iob twice for adapter in slot slot.
Description: The device driver has freed the same private buffer to the adapter twice. This could cause data corruption.
Action: If the problem persists, contact Software Support.
ESC.029 |
Level: UI_ERROR
Short Syntax: ESC.029 Unable to create dump file for ESCON adapter in slot slot. RC=0x rc
Long Syntax: ESC.029 Unable to create dump file for ESCON adapter in slot slot. RC=0x rc
Description: A fatal error was detected by the ESCON adapter microcode, but the device drive was unable to create a dump file. If this error did not occur as a result of removing the fiber, contact Software Support.
ESC.030 |
Level: UI_ERROR
Short Syntax: ESC.030 Dump file ' filename' created for the ESCON adapter in slot slot.
Long Syntax: ESC.030 Dump file ' filename' created for the ESCON adapter in slot slot.
Description: A fatal error was detected by the ESCON adapter microcode, and a dump file was created containing failure information. If this error did not occur as a result of removing the fiber, contact Software Support.
ESC.031 |
Level: C-INFO
Short Syntax: ESC.031 ESCON DD rcvd Logical Path Removed notif from slot slot,link addr=0x link, LPAR=0x lpar,cu-num=0x cu_num.
Long Syntax: ESC.031 ESCON DD received a Logical Path Removed notification from slot slot ESCON adapter, link addr=0x link, LPAR=0x lpar, cu-num=0x cu_num.
Description: The ESCON adapter has made removed a connection to the host via one of the configured subchannel paths.
ESC.032 |
Level: UE-ERROR
Short Syntax: ESC.032 Unknown ESCON adapter CCA error, nt network, subchan= subchan, cca0=0x cca0, cca1=0x cca1, rc=0x rc.
Long Syntax: ESC.032 Unknown ESCON adapter CCA error, network network, subchan= subchan, cca0=0x cca0, cca1=0x cca1, rc=0x rc.
Description: This is an unknown CCA error message being reported by the ESCON adapter.
Action: Typically, no action is required. If the problem persists, contact Software Support. Refer to the documentation for further information.
ESC.033 |
Level: UE-ERROR
Short Syntax: ESC.033 ESCON adapter CCA error, nt network, ccamsg, subchan= subchan, cca0=0x cca0, cca1=0x cca1, rc=0x rc.
Long Syntax: ESC.033 ESCON adapter CCA error, network network, ccamsg, subchan= subchan, cca0=0x cca0, cca1=0x cca1, rc=0x rc.
Description: The ESCON adapter is reporting a CCA error to the ESCON device driver.
Action: Typically, no action is required. If the problem persists, contact Software Support. Refer to the documentation for further information.
ESC.034 |
Level: ALWAYS
Short Syntax: ESC.034 ESCON in slot slot. AIB FLASH mismatch: code at 0x codelev, adapter at 0x adaplev
Long Syntax: ESC.034 ESCON adapter in slot slot. AIB FLASH mismatch: code at 0x codelev, adapter at 0x adaplev
Description: The ESCON adapter has FLASH code that is different from the level available with the current load image.
Action: Contact Software Support to determine if the FLASH code on the adapter should be updated.
ESC.035 |
Level: C-INFO
Short Syntax: ESC.035 ESCON adapter in slot slot is operational.
Long Syntax: ESC.035 ESCON adapter in slot slot is operational.
Description: The ESCON adapter is operational. The adapter has not yet made a connection to the host.
ESC.036 |
Level: UI-ERROR
Short Syntax: ESC.036 ESCON adapter error, slot= slot, subchan= subchan, rc= rc, origcmd= origcmd, sev= sev, correl=0x correl.
Long Syntax: ESC.036 ESCON DD received an Error notif from slot slot ESCON adapter; subchan= subchan, rc = rc, origcmd= origcmd, severity= sev, correl=0x correl.
Description: The ESCON adapter is reporting an error to the ESCON device driver.
Action: Typically, no action is required. If the problem persists, contact Software Support. Refer to the documentation for further information.
ESC.037 |
Level: UI-ERROR
Short Syntax: ESC.037 ESCON adapter in slot= slot is offline to the host.
Long Syntax: ESC.037 ESCON adapter in slot= slot is offline to the host.
Description: The ESCON adapter is reporting that it is offline to the host. The adapter will be automatically restarted. Diagnostics will be invoked if the adapter fails to restart.
Action: If the adapter passes diagnostics but fails to start, contact Software Support.
ESC.038 |
Level: UI-ERROR
Short Syntax: ESC.038 ESCON DD received i960 Processor Fault notif from slot= slot ESCON adapter, Fault Type=0x ft.
Long Syntax: ESC.038 ESCON DD received an i960 Processor Fault notif from slot slot ESCON adapter with Fault Type=0x ft.
Description: The ESCON adapter is reporting that it had an i960 processor fault. The adapter will be automatically restarted. Diagnostics will be invoked if the adapter fails to start.
Action: Contact Software Support.
ESC.039 |
Level: UI-ERROR
Short Syntax: ESC.039 ESCON DD received SLC2 NMI Detected notif from slot= slot ESCON adapter.
Long Syntax: ESC.039 ESCON DD received an SLC2 NMI Detected notif from slot slot ESCON adapter.
Description: The ESCON adapter is reporting that it detected an SLC2 NMI error. The adapter will be automatically restarted. Diagnostics will be invoked if the adapter fails to restart.
Cause: This may be the result of disconnecting the ESCON fiber from the ESCON adapter and then reconnecting it.
Action: Contact Software Support.
ESC.040 |
Level: U-INFO
Short Syntax: ESC.040 ESCON adapter in slot slot had an unexpected interrupt.
Long Syntax: ESC.040 ESCON DD received an Unexpected Interrupt notification from slot slot ESCON adapter.
Description: ESCON adapter had an unexpected interrupt. If the problem persists, contact Software Support.
ESC.041 |
Level: UI-ERROR
Short Syntax: ESC.041 ESCON adapter in slot slot had a serial engine failure, dump is log_stat.
Long Syntax: ESC.041 ESCON DD received a Serial Engine Failure notification from slot slot ESCON adapter, dump is log_stat.
Description: The ESCON adapter is reporting that it had a serial engine failure. The adapter will be automatically restarted. Diagnostics will be invoked if the adapter fails to restart.
Cause: This may be the result of disconnecting the ESCON fiber from the ESCON adapter and then reconnecting it.
Action: If the adapter fails to restart, contact Software Support.
ESC.042 |
Level: UI-ERROR
Short Syntax: ESC.042 Slot slot ESCON adapter microcode aborted with rc=0x rc.
Long Syntax: ESC.042 ESCON DD received a Microcode Aborted notification from slot slot ESCON adapter, rc=0x rc.
Description: The ESCON adapter is reporting that the microcode aborted. The adapter will be automatically restarted. Diagnostics will be invoked if the adapter fails to restart.
Cause: This may be the result of disconnecting the ESCON fiber from the ESCON adapter and then reconnecting it.
Action: If the adapter fails to restart, contact Software Support.
ESC.043 |
Level: C-INFO
Short Syntax: ESC.043 ESCON DD rcvd Logical Path Estbl notif from slot slot,link addr=0x link, LPAR=0x lpar,cu-num=0x cu_num.
Long Syntax: ESC.043 ESCON DD received a Logical Path Established notification from slot slot ESCON adapter, link addr=0x link, LPAR=0x lpar, cu-num=0x cu_num.
Description: The ESCON adapter has made a connection to the host via one of the configured subchannel paths.
ESC.044 |
Level: UI-ERROR
Short Syntax: ESC.044 ESCON adapter in slot slot had a POST error, error = 0x error.
Long Syntax: ESC.044 ESCON adapter in slot slot has a POST error, error = 0x error.
Description: The ESCON adapter had a POST error. The adapter will be automatically restarted. Diagnostics will be invoked if the adapter fails to restart.
Action: If adapter fails to restart, contact Software Support.
ESC.045 |
Level: UI-ERROR
Short Syntax: ESC.045 ESCON adapter in slot slot had a POST error, CBSP value=0x error.
Long Syntax: ESC.045 ESCON adapter in slot slot had a POST error, CBSP value=0x error.
Description: The ESCON adapter had a POST error. The adapter will be automatically restarted. Diagnostics will be invoked if the adapter fails to restart.
Action: If adapter fails to restart, contact Software Support.
ESC.046 |
Level: UI-ERROR
Short Syntax: ESC.046 ESCON adapter in slot slot did not complete POST.
Long Syntax: ESC.046 ESCON adapter in slot slot did not complete POST.
Description: The ESCON adapter did not complete POST. The adapter will be automatically restarted. Diagnostics will be invoked if the adapter fails to restart.
Action: If the adapter passes diagnostics but fails to restart, contact Software Support.
ESC.047 |
Level: UI-ERROR
Short Syntax: ESC.047 ESCON adapter in slot slot had a PrePOST error = 0x error.
Long Syntax: ESC.047 ESCON adapter in slot slot had a PrePOST error = 0x error.
Description: The ESCON adapter had a PrePOST error. The adapter will be automatically restarted. Diagnostics will be invoked if the adapter fails to restart.
Action: If the adapter does not restart, contact Software Support.
ESC.048 |
Level: UI-ERROR
Short Syntax: ESC.048 Slot slot does not contain an ESCON card, identifier = id.
Long Syntax: ESC.048 Slot slot does not contain an ESCON card, identifier = id.
Description: The slot does not contain an ESCON card and the software has been configured for an ESCON adapter in that slot.
Action: Correct the configuration. If the problem occurs after reconfiguration, contact Software Support.
ESC.049 |
Level: UI-ERROR
Short Syntax: ESC.049 Slot slot ESCON Adapter timed-out during initialization, cmd=0x cmd.
Long Syntax: ESC.049 Slot slot ESCON Adapter timed-out during initialization, cmd=0x cmd.
Description: The adapter will be automatically restarted.
Action: If the adapter does not restart, contact Software Support.
ESC.050 |
Level: UI-ERROR
Short Syntax: ESC.050 Slot slot ESCON Control Unit table did not load correctly, rc=0x rc, tbl=0x tbl_num.
Long Syntax: ESC.050 Slot slot ESCON Control Unit table did not load correctly, rc=0x rc, tbl=0x tbl_num.
Description: The ESCON adapter cannot start properly without these tables. The adapter will be automatically restarted.
Action: If the adapter does not restart, contact Software Support.
ESC.051 |
Level: UI-ERROR
Short Syntax: ESC.051 ESCON DD could not obtain a Control Buffer from slot slot adapter.
Long Syntax: ESC.051 ESCON DD could not obtain a Control Buffer from adapter in slot slot.
Description: The device driver requires a buffer from the adapter. If the adapter cannot provide the buffer then the adapter is not functioning properly. The adapter will be restarted automatically.
Action: If the problem persists, contact Software Support.
ESC.052 |
Level: UI_ERROR
Short Syntax: ESC.052 file( line): ESCON DD encountered an internal error for slot slot. Identifier = id.
Long Syntax: ESC.052 file( line): ESCON DD encountered an internal error for slot slot. Identifier = id.
Description: The ESCON device driver has encountered a condition that it cannot handle properly.
Action: If the problem persists, contact Software Support.
ESC.053 |
Level: UI-ERROR
Short Syntax: ESC.053 ESCON DD detected a CRC error in CU Table tbl_num for slot slot.
Long Syntax: ESC.053 ESCON DD detected a CRC error in CU Table tbl_num for slot slot.
Description: The adapter will be restarted automatically.
Action: If the problem persists, contact Software Support.
ESC.054 |
Level: UI-ERROR
Short Syntax: ESC.054 ESCON DD could not obtain system memory; slot=0x slot, identifier= id.
Long Syntax: ESC.054 ESCON DD could not obtain system memory; slot=0x slot, identifier= id.
Description: If this error occurred during initialization, the adapter will be restarted.
Action: If the problem persists, contact Software Support.
ESC.055 |
Level: UI-ERROR
Short Syntax: ESC.055 ESCON DD could not open dump files on harddrive. Dumps not available for slot slot adapter.
Long Syntax: ESC.055 ESCON DD could not open the dump files on the harddrive. The dumps are not available for slot slot adapter
Description: The device driver attempted to open a file on the harddrive but was unsuccessful. The dump of the ESCON adapter is not available.
Action: If problems with the adapter persist, contact Software Support.
ESC.056 |
Level: UI-ERROR
Short Syntax: ESC.056 ESCON DD could not dump all slot slot ESCON adapter data_type data to the dump file.
Long Syntax: ESC.056 ESCON DD could not dump all of the slot slot ESCON adapter data_type data to the dump file on the harddrive.
Description: The device driver attempted to dump the ESCON adapter data to a file on the harddrive. The IRAM dump may be partially available in c:\ESCONIx.DMP, where x is the slot number. The DRAM dump may be partially available in c:\ESCONDx.DMP, where x is the slot number.
Action: Contact Software Support.
ESC.057 |
Level: C-INFO
Short Syntax: ESC.057 ESCON DD received a reset subchannel notif for subchannel 0x sc, slot= slot.
Long Syntax: ESC.057 ESCON DD received a reset subchannel notification for subchannel 0x sc, slot= slot.
Description: The device driver received a reset subchannel notification.
ESC.058 |
Level: C-INFO
Short Syntax: ESC.058 Incorrect subchannel configuration detected for slot slot ESCON adapter.
Long Syntax: ESC.058 Incorrect subchannel configuration detected for slot slot ESCON adapter.
Description: The device driver has detected that a subchannel configuration is incorrect. Correctly configured subchannels should not be affected by this problem.
Action: Correct the configuration.
ESC.059 |
Level: UI-ERROR
Short Syntax: ESC.059 ESCON DD(slot slot adapter): Command FIFO full threshold= count.
Long Syntax: ESC.059 ESCON DD(slot slot adapter): Command FIFO full threshold= count.
Description: The device driver requires a Command FIFO entry in order to communicate with the adapter. If the adapter cannot obtain an entry during initialization, the adapter will be restarted. If the adapter cannot obtain an entry at any other time, the internal software will attempt to recover. This error will only cause real problems for LSA.
Action: If the problem persists, contact Software Support.
ESC.060 |
Level: P-TRACE
Short Syntax: ESC.060 ESCON DD sending frame from slot= slot,, subchan= subchan,, LT= lantype,, LN= lannum, to base net.
Long Syntax: ESC.060 ESCON DD rcvd frame from slot slot, ESCON, subchan= subchan,, LanType= lantype,, and LanNum= lannum; sending it to base net.
Description: A frame was received by the channel and was sent to the ESCON base net handler.
ESC.061 |
Level: P-TRACE
Short Syntax: ESC.061 ESCON DD rcvd frame from net handler for slot= slot,, subchan= subchan,, LT= lantype,, LN= lannum,,PDU-hdr= pdu_len
Long Syntax: ESC.061 ESCON DD received a frame from a net handler destined for slot slot, ESCON adapter, subchan= subchan,, LanType= lantype,, and LanNum= lannum,, PDU-header len= pdu_len.
Description: An ESCON-related nethandler sent the ESCON DD a frame to transmit.
ESC.062 |
Level: P-TRACE
Short Syntax: ESC.062 ESCON DD rcvd cmd, cmd from net handler for slot slot ESCON.
Long Syntax: ESC.062 ESCON DD received cmd, command from net handler for slot slot ESCON adapter.
Description: An ESCON-related net handler sent the ESCON DD a command.
ESC.063 |
Level: P-TRACE
Short Syntax: ESC.063 ESCON DD rcvd cmd, cmd from nethandler for slot slot, ESCON, subchan= subchan.
Long Syntax: ESC.063 ESCON DD received cmd, command from a nethandler for slot slot, ESCON adapter, subchan= subchan.
Description: An ESCON-related net handler sent the ESCON DD a command.
ESC.064 |
Level: P-TRACE
Short Syntax: ESC.064 ESCON DD sent notif, notif for slot slot, ESCON, subchan= subchan,, LT= lantype,, LN= lannum, to nethandler.
Long Syntax: ESC.064 ESCON DD sent notif, notif for slot slot, ESCON adapter, subchan= subchan,, LT= lantype,, LN= lannum, to nethandler.
Description: The ESCON device driver sent a notification to an ESCON-related net handler
ESC.065 |
Level: U-INFO
Short Syntax: ESC.065 ESCON adapter ran out of rcv buffers, LCS frame discarded, slot= slot, local sc= subchan
Long Syntax: ESC.065 ESCON adapter ran out of receive buffers and discarded an LCS frame; slot= slot local subchan= subchan.
Description: The ESCON adapter is reporting that it discarded an LCS frame because it could not obtain a receive buffer.
Action: Typically, no action is required. If the problem persists, increase the number of receive buffers for this ESCON adapter.
ESC.066 |
Level: UI-ERROR
Short Syntax: ESC.066 ESCON adapter ran out of rcv buffers, LSA frame discarded, slot= slot, local sc= subchan
Long Syntax: ESC.066 ESCON adapter ran out of receive buffers and discarded an LSA frame; slot= slot local subchan= subchan.
Description: The ESCON adapter is reporting that it discarded an LSA frame because it could not obtain a receive buffer.
Action: Increase the number of receive buffers for this ESCON adapter.
ESC.067 |
Level: U-INFO
Short Syntax: ESC.067 ESCON adapter ran out of rcv buffers, MPC+ frame discarded, slot= slot, local sc= subchan
Long Syntax: ESC.067 ESCON adapter ran out of receive buffers and discarded an MPC+ frame; slot= slot local subchan= subchan.
Description: The ESCON adapter is reporting that it discarded an MPC+ frame because it could not obtain a receive buffer.
Action: Typically, no action is required. If the problem persists, increase the number of receive buffers for this ESCON adapter.
Panic escnomem |
Short Syntax: escnomem: ESCON handler no memory
Description: An ESCON handler cannot allocate memory for control block(s).
Action: Contact customer service.
Panic escnsram |
Short Syntax: escnsram: ESCON SRAM not found
Description: The SRAM record for an ESCON handler could not be found.
Action: Contact customer service.
Panic escbprt |
Short Syntax: escbprt: bad prot init
Description: An unsupported Network Layer protocol tried to initialize an ESCON handler.
Action: Contact customer service.
Panic escdreg |
Short Syntax: escdreg: virt net already reg
Description: An ESCON virtual net handler has already registered with the base.
Action: Contact customer service.
Panic escbreq |
Short Syntax: escbreq: bad xmit rqst
Description: An unsupported protocol packet was given to the ESCON handler for transmission.
Action: Contact customer service.
Panic escnosub |
Short Syntax: escnosub: subch not found
Description: The requested logical path and device address was not found in the ESCON base handler subchannel table.
Action: Contact customer service.
Panic escbcall |
Short Syntax: escbcall: bad call to routine.
Description: An invalid call was made to a routine.
Action: Contact customer service.
Panic escbprd |
Short Syntax: escbprt: bad prot down
Description: An unsupported Network Layer protocol tried to uninitialize an ESCON handler.
Action: Contact customer service.